Does your business need emergency doors?

 

Not every business premises needs a separate emergency-only exit or a dedicated steel exit door.

For premises covered by the Regulatory Reform (Fire Safety) Order 2005 in England and Wales, the requirement is to provide adequate means of escape for the people using the building.

The appropriate arrangements depend on the premises’ layout, use, occupancy and fire hazards, informed by a suitable and sufficient fire risk assessment.

A building’s description does not, by itself, establish an exemption.

WHEN MIGHT ADDITIONAL EMERGENCY EXITS BE NEEDED?

Under the Regulatory Reform Fire Safety Order 2005, responsible persons for premises within its scope in England and Wales must ensure that people can escape safely in an emergency.

A separate emergency-only door may not be necessary where the normal entrance and existing escape arrangements are adequate. This is not an exemption from providing safe escape routes.

The following situations can call for additional or specially equipped exits. The number, location and specification of doors must be assessed for a particular premises.

  • Workplaces with complex layouts or escape routes may need additional exits. Having fewer than five employees, or only one room, does not automatically remove the need for adequate escape arrangements.

  • Factories, warehouses and industrial facilities will need multiple emergency exits based around travel distances if they are to comply with current UK health and safety legislation.

  • Buildings with high foot traffic from employees or visitors or if they are located over several floors or storeys should have adequate fire exit doors on each and every level

  • Schools, cinemas, restaurants, shops and other public buildings including hospitals must have accessible and properly signed emergency and fire exits that are also compliant with panic hardware.

All emergency doors have to be obviously and clearly marked, unobstructed and be easy to open without needing a code or a key from the inside. The UK government’s Fire Safety: Approved Document B’s guidance sets out the requirement for doors to open in the direction of escape wherever reasonably practicable, and always where more than 60 people might use the door during a fire, where there is very high fire risk or a building with potential for rapid growth.

An inward-opening doorset may be acceptable for smaller numbers where site constraints dictate covered by a fire risk assessment.

There is no blanket exemption for the following premises and whether an additional emergency-only exit is needed depends on the risks and existing escape arrangements.

  • Gyms, social clubs and similar facilities: private or members-only use does not, by itself, establish an exemption. Exit provision must account for the number and needs of occupants, the layout and the fire risks.

  • Small offices and shops: a separate emergency-only exit may not be necessary where the normal entrance provides adequate escape. A simple layout or fewer than five employees is not an automatic exemption; the fire risk assessment must consider occupancy, travel distances and hazards.

  • Plant rooms, storage units and back-of-house areas: these are not automatically exempt. Their use, hazards and escape arrangements must be assessed to determine the necessary exit provision and door specification.

 

DIFFERENCES BETWEEN EMERGENCY EXIT DOORS AND FIRE EXIT DOORS

“Emergency exit door” and “fire exit door” are overlapping terms, not necessarily different types of door. Fire-safety legislation uses the term “emergency doors” when setting requirements for escape. The important distinction is between a door that allows people to escape and a fire-resisting door that helps limit the spread of fire.

FIRE EXIT DOORS

A fire exit door usually means the final door on an escape route, leading out of the building to a place of safety. Its primary purpose is to allow people to leave quickly and safely. It may also be a normal entrance or exit; it does not have to be reserved for emergencies. Doors used for escape must be readily usable from the escape side without a key or specialist knowledge.

A fire exit door is not automatically a fire-resisting door. A fire-resisting door is designed to resist fire spread for a specified period, helping protect escape routes or separate parts of a building. Some doors must perform both functions, in which case both the escape and fire-resistance requirements apply.

emergency doors

EMERGENCY DOORS OPERATIONS

“Emergency exit door” is a broader description of a door used for emergency escape, including during a fire. The name alone does not establish a separate technical specification. In England and Wales, Article 14 of the Regulatory Reform (Fire Safety) Order 2005 sets requirements for emergency routes and exits where necessary to safeguard people, including keeping them clear and ensuring that doors can be easily and immediately opened.

Calling a door an “emergency door” rather than a “fire exit door” does not, by itself, justify a push pad instead of a panic bar. The appropriate exit hardware depends on the people likely to use the door, their familiarity with its operation and whether panic conditions can be foreseen.

External escape doorsets require independent third-party certification of their “ability to release” under BS EN 14351-1, covering the complete doorset and factory production controls—not just the panic bar or push pad.

The distinction between panic exit devices and emergency exit devices concerns the hardware and its intended conditions of use:

  • BS EN 1125 covers panic exit devices operated by a horizontal push bar or touch bar. These are intended for situations where panic can be foreseen and users may have no prior knowledge of the device, such as final exits used by the public in shops or entertainment venues.

  • BS EN 179 covers emergency exit devices operated by a lever handle or push pad. These are intended for situations where users are familiar with the exit and its hardware and panic is unlikely. Low footfall alone is not a sufficient basis for choosing this hardware.

Names used in specifications and signage may overlap or describe the material or hardware rather than a different escape function. Examples include:

  • Emergency exit doors

  • Fire escape doors

  • Panic escape doors

  • Panic bar doors

  • Push-bar exit doors

Metador offers all kinds of compliant steel doors so it doesn’t matter if your specifications are for public spaces, industrial/business sites or private facilities – you can be confident that your doors will meet the right legal standards.